HP ProLiant Smart Array 5x and 6x Controller Driver for Windows 2000/Windows Server 2003 By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee. Type: | Driver - Storage Controller | Version: | 5.70.0.32(13 Apr 2006) | Operating System(s): | Microsoft Windows Server 2003 | Microsoft Windows Storage Server 2003 | Microsoft Windows 2000 | File name: | cp005778.exe (365 KB) |
This component provides support for HP ProLiant Smart Array 5x and 6x Controllers. Driver version 5.44.0.32 and newer added support for the HP Smart Array 641/642 controllers. Driver version 5.46.2.32 and newer added support for the HP Smart Array 6402 controller. Driver version 5.48.0.32 and newer added support for the HP Smart Array 6404 controller. Driver version 5.60.0.32 and newer added support for the HP Smart Array 6i controller. Component installer was enhanced to leave the component XML file (cpxxxxxx.xml) in a known location (%SystemDrive%CPQSYSTEM) so the HP Management and Version Control agents can retrieve information about the installed components on the server. Installation: If you have not already done so, copy all of the extracted Compaq Smart Array 5300 Controller Driver files to a disk which we will refer to as the Driver Disk. Insert the Windows 2000/Server 2003 CD to begin the installation process. If prompted, press any key to boot from the CD. When Windows 2000/Server 2003 Setup displays the message 'Press F6 if you need to install a third party SCSI or RAID driver”, press 'F6'. When Windows 2000/Server 2003 Setup displays the message 'Setup could not determine the type of one or more mass storage devices installed in your system, or you have chosen to manually specify an adapter,' press 'S' to specify an addition device. Insert the disk with the extracted Compaq Smart Array 5300 Controller Driver files and press ENTER. Select the controller from the list displayed and press ENTER. Press Enter and continue the installation of Windows 2000/Server 2003. End User License Agreements: Hewlett-Packard End User License Agreement
Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Resolved the following:
- Issue where the cpqcisse driver logs incorrect information into the IML when Cabinet, Chassis, and Bay are all zero.
- Issue where the cpqcisse driver causes a blue screen with Bug check 0x24 when driver verifier is enabled.
- Issue where cpqcisse reported incorrect drive information upon detecting an Unrecoverable Read Error for a drive installed in a HP Modular Smart Array 20 Enclosure.
Version:5.80.0.32 (C) (18 Aug 2009) No functional changes have occurred for the driver, only enhanced component-level logging has been implemented in the smart component installer. The generated log file will be located on the target system in %SYSTEMROOT%cpqsystemlog directory under the name CPQSETUP.LOG. If you have previously installed version 5.80.0.32(B) of this driver, then you do not need to upgrade to version 5.80.0.32(C). Version:5.80.0.32 (B) (18 Feb 2009) No functional changes have occurred for the driver, only the component installer has been updated to recognize if it is running within a virtualized guest environment. If you have previously installed version 5.80.0.32 of this driver, then you do not need to upgrade to version 5.80.0.32(B). Version:5.80.0.32 (31 Mar 2008) Smart Array 5x and 6x Controller Driver (cpqcissm.sys): - Incremented version number
Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Corrected an issue where events would incorrectly identify the location of a failed fan or power supply in certain configurations.
Smart Array 5x and 6x Controller Driver (cpqcissm.sys): Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Added new events to support the HP StorageWorks 20 Modular Smart Array Enclosure
Version:5.78.0.32 (25 Jul 2007) Smart Array 5x and 6x Controller Driver (cpqcissm.sys): - Incremented version number
Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Corrected an issue where events would incorrectly identify the location of a failed fan or power supply in certain configurations.
Smart Array 5x and 6x Controller Driver (cpqcissm.sys): Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Added new events to support the HP StorageWorks 20 Modular Smart Array Enclosure
Version:5.76.0.32 (27 Apr 2007) Smart Array 5x and 6x Controller Driver (cpqcissm.sys): - Incremented version number
Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Corrected an issue where events would incorrectly identify the location of a failed fan or power supply in certain configurations.
Smart Array 5x and 6x Controller Driver (cpqcissm.sys): Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Added new events to support the HP StorageWorks 20 Modular Smart Array Enclosure
Version:5.74.0.32 (13 Dec 2006) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Smart Array 5x and 6x Controller Driver (cpqcissm.sys) Resolved a WHQL SCSI compliance issue when the driver was used with the MSA 500 G2 storage enclosure. Version:5.72.0.32(B) (25 Sep 2006) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Resolved an issue where CPQCISSE reported incorrect MSA20 box number when two MSA20's are connected. Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Updated Version Major Number for SmartStart 7.60.
Smart Array 5x and 6x Controllers SCSI Miniport Driver (cpqcissm) Updated Version Major Number for Smart Start 7.60. Version:5.70.0.32 (13 Apr 2006) Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Resolved the following:
- Issue where the cpqcisse driver logs incorrect information into the IML when Cabinet, Chassis, and Bay are all zero.
- Issue where the cpqcisse driver causes a blue screen with Bug check 0x24 when driver verifier is enabled.
- Issue where cpqcisse reported incorrect drive information upon detecting an Unrecoverable Read Error for a drive installed in a HP Modular Smart Array 20 Enclosure.
Component installer was enhanced to leave the component XML file (cpxxxxxx.xml) in a known location (%SystemDrive%CPQSYSTEM) so the HP Management and Version Control agents can retrieve information about the installed components on the server. Version:5.68.0.32 (9 Sep 2005) Resolved an issue where the cpqcisse driver does not work with external arrays. Updated Version Major Number for SmartStart 7.40. Version:5.66.0.32 (25 Apr 2005) Resolved the following:
- Issue wherein prior to hibernation, all the I/O was not completed and hence the controller cache was not flushed.
- Issue that can cause the Event Notification driver to crash when there are more than 7 disk drives on a SCSI Bus.
Version:5.64.0.32 (14 Feb 2005) Resolved a raidscan blue screen problem. Separated the cpqcissm.dll (DME) from the cpqcissm.sys driver package.
Updated the INF for 32 bit and 64 bit compatibility.
Increased the heartbeat timeout value during a firmware flash. Version:5.62.0.32 (18 Aug 2004) Updated controller lockup criteria to four minutes when flashing the controllers firmware. This is a driver workaround to accommodate the extended time required to update SA 6x firmware to revision 2.26. Version:5.60.0.32 (18 Jun 2004) Resolved the following:
- Bus reset issue
- Issue where events may be reported incorrectly when an external controller is removed and reinserted.
The driver now limits the number of commands sent to one for all logical Luns devices on the given external bus for Bus Resets.Driver now enables Pre-fetch for i386 based 6x controllers, thus improving performance. Firmware default is off. Added 4 point ID to txtsetup.oem for all SA5x and 6x. Version:5.49.2.32 (8 Mar 2004) Enabled Pre-fetch support to work in conjunction with HP ProLiant Smart Array 6x Controller Firmware version 1.92 or later for optimal performance. Version:5.48.0.32 (17 Dec 2003) Resolved the following:
- Spelling and grammatical errors in an event ids 24588, 24655, 24657, 24664.
- Issue with incomplete text displayed when event id 24606 is logged.
- Issue with a NTFS.sys E3 bug check that occurs when a drive fails in a RAID 0 raid set.
- Updated MapBuffers Parameter in the driver in order to prevent the system from using unecessary resources and additional memory.
Added the following:
- Documentation that lists the event log information posted by CPQCISSE.SYS.
- Support for the Smart Array 6404 Controller and Smart Array 6400 Controller.
- Added support for new location format:
Cabinet:Bay:Chassis:Slot
Version:5.46.2.32 (1 Jul 2003) Resolved the following:
- Events not being displayed correctly in DME.
- Updated naming convention for Array Configuration Utility(ACU).
- Removed references to Compaq within resource string files.
- Removed “Driver Posting Dialog Box”.
- Online flashing firmware issue with the SA641 and SA642 controller.
- Events reported on internal storage devices reported as external storage devices.
Modified the installer to disallow 32-bit drivers/applications from installing on 64-bit operating systems. Added support for the HP Smart Array 641/642/6402 controllers.Added support for Windows Server 2003. Updated INF to support DME on Windows Server 2003. Added Japanese translation.
Version:5.44.0.32 (11 Apr 2003) Resolved issue where in the IML event log, when a power failure was repaired, the failure was incremented instead of being updated to repaired.Resolved issue that was preventing Cpqcissm.dll from loading on Windows Server 2003. Added Japanese string support. Version:5.42.2.32 (12 Feb 2003) Updated the following:
- Resolved insertion string exceeding maximum length for logical drive change status event.
- Resolved issue with freeing all memory pools prior to unload for hot plug drive events.
- IMD and IML post some storage events inaccurately while other storage events do not get posted at all.
- Resolved issue where a tape drives Target ID increments by one and causes a unsafe removal message after every rescan of the device manager.
- Minimized the number of reads required to validate that the controller is alive and not locked up. This change should provide a a slight performance boost.
- Resolved an issue where filtered events where not being displayed under various multi language OS releases.
- Modified Redundancy page to not show disks that were on inactive nodes of a cluster.
Updated the following:
- Changed the max number of outstanding requests to 127 from 255.
- Changed the algorithm for checking the controller heartbeat to do less PCI configuration space reads. This may increase performance is some instances.
- Added support for Selective Storage Presentation.
- Added new Cache events for Internal Array Controllers.
- Added startup event and Cpqcisse.sys failed to start event.
- Added Snapshot events.
- Added new event codes for Physical Drive, Hardware Errors, Snapshot, and License keys
- Added new Cache events for Internal Array Controllers.
- Added property page for redundant controller paths.
Version:5.40.2.0 (D) (4 Dec 2002) Enhanced functionality. Version:5.40.2.0 (C) (15 Oct 2002) Updated for rebranding. Version:5.40.2.0 (B) (11 Jun 2002) Added support for Windows Server 2003. Version:5.40.2.0 (5 Jun 2002) Modified CPQCISSE to prevent logging all physical drive failure events to the IML as 'bay unknown'.Modified CPQCISSM.SYS to fix hibernation. Updated copyright information. Version:5.16.2.0 (B) (18 Jan 2002) Added text setup installation support for Microsoft Windows Server 2003. Version:5.16.2.0 (17 Jan 2002) Updated to prevent a potential system hang when waiting for Health Driver to load completely. Added support for:
- Smart Array 5312
- Clustering
Added new signatures for Cpqcissm and Cpqcisse. Version:5.12.88.0 (26 Sep 2001) Modified to enhance overall performance. Updated to correct potential problem when hot adding or removing drives. The event viewer may report the drives incorrectly. Version:5.10.84.0 (27 Jun 2001) Enhanced the installer to work with future deployment utilities. Version:5.8.76.0 (12 Apr 2001) Version:5.3.44.0 (11 Oct 2000) Type: | Driver - Storage Controller | Version: | 5.70.0.32(13 Apr 2006) | Operating System(s): | Microsoft Windows 2000 | Microsoft Windows Server 2003 | Microsoft Windows Storage Server 2003 |
|
DescriptionThis component provides support for HP ProLiant Smart Array 5x and 6x Controllers. Driver version 5.44.0.32 and newer added support for the HP Smart Array 641/642 controllers. Driver version 5.46.2.32 and newer added support for the HP Smart Array 6402 controller. Driver version 5.48.0.32 and newer added support for the HP Smart Array 6404 controller. Driver version 5.60.0.32 and newer added support for the HP Smart Array 6i controller. EnhancementsComponent installer was enhanced to leave the component XML file (cpxxxxxx.xml) in a known location (%SystemDrive%CPQSYSTEM) so the HP Management and Version Control agents can retrieve information about the installed components on the server. Installation InstructionsInstallation: If you have not already done so, copy all of the extracted Compaq Smart Array 5300 Controller Driver files to a disk which we will refer to as the Driver Disk. Insert the Windows 2000/Server 2003 CD to begin the installation process. If prompted, press any key to boot from the CD. When Windows 2000/Server 2003 Setup displays the message 'Press F6 if you need to install a third party SCSI or RAID driver”, press 'F6'. When Windows 2000/Server 2003 Setup displays the message 'Setup could not determine the type of one or more mass storage devices installed in your system, or you have chosen to manually specify an adapter,' press 'S' to specify an addition device. Insert the disk with the extracted Compaq Smart Array 5300 Controller Driver files and press ENTER. Select the controller from the list displayed and press ENTER. Press Enter and continue the installation of Windows 2000/Server 2003. Release NotesEnd User License Agreements: Hewlett-Packard End User License Agreement
FixesSmart Array 5x and 6x Notification Driver (cpqcisse.sys) Resolved the following:
- Issue where the cpqcisse driver logs incorrect information into the IML when Cabinet, Chassis, and Bay are all zero.
- Issue where the cpqcisse driver causes a blue screen with Bug check 0x24 when driver verifier is enabled.
- Issue where cpqcisse reported incorrect drive information upon detecting an Unrecoverable Read Error for a drive installed in a HP Modular Smart Array 20 Enclosure.
Revision HistoryVersion:5.80.0.32 (C) (18 Aug 2009) No functional changes have occurred for the driver, only enhanced component-level logging has been implemented in the smart component installer. The generated log file will be located on the target system in %SYSTEMROOT%cpqsystemlog directory under the name CPQSETUP.LOG. If you have previously installed version 5.80.0.32(B) of this driver, then you do not need to upgrade to version 5.80.0.32(C). Version:5.80.0.32 (B) (18 Feb 2009) No functional changes have occurred for the driver, only the component installer has been updated to recognize if it is running within a virtualized guest environment. If you have previously installed version 5.80.0.32 of this driver, then you do not need to upgrade to version 5.80.0.32(B). Version:5.80.0.32 (31 Mar 2008) Smart Array 5x and 6x Controller Driver (cpqcissm.sys): - Incremented version number
Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Corrected an issue where events would incorrectly identify the location of a failed fan or power supply in certain configurations.
Smart Array 5x and 6x Controller Driver (cpqcissm.sys): Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Added new events to support the HP StorageWorks 20 Modular Smart Array Enclosure
Version:5.78.0.32 (25 Jul 2007) Smart Array 5x and 6x Controller Driver (cpqcissm.sys): - Incremented version number
Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Corrected an issue where events would incorrectly identify the location of a failed fan or power supply in certain configurations.
Smart Array 5x and 6x Controller Driver (cpqcissm.sys): Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Added new events to support the HP StorageWorks 20 Modular Smart Array Enclosure
Version:5.76.0.32 (27 Apr 2007) Smart Array 5x and 6x Controller Driver (cpqcissm.sys): - Incremented version number
Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Corrected an issue where events would incorrectly identify the location of a failed fan or power supply in certain configurations.
Smart Array 5x and 6x Controller Driver (cpqcissm.sys): Smart Array 5x and 6x Controller Event Notification Driver (cpqcisse.sys): - Added new events to support the HP StorageWorks 20 Modular Smart Array Enclosure
Version:5.74.0.32 (13 Dec 2006) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Smart Array 5x and 6x Controller Driver (cpqcissm.sys) Resolved a WHQL SCSI compliance issue when the driver was used with the MSA 500 G2 storage enclosure. Version:5.72.0.32(B) (25 Sep 2006) Upgrade Requirement: Recommended - HPE recommends users update to this version at their earliest convenience. Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Resolved an issue where CPQCISSE reported incorrect MSA20 box number when two MSA20's are connected. Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Updated Version Major Number for SmartStart 7.60.
Smart Array 5x and 6x Controllers SCSI Miniport Driver (cpqcissm) Updated Version Major Number for Smart Start 7.60. Version:5.70.0.32 (13 Apr 2006) Smart Array 5x and 6x Notification Driver (cpqcisse.sys) Resolved the following:
- Issue where the cpqcisse driver logs incorrect information into the IML when Cabinet, Chassis, and Bay are all zero.
- Issue where the cpqcisse driver causes a blue screen with Bug check 0x24 when driver verifier is enabled.
- Issue where cpqcisse reported incorrect drive information upon detecting an Unrecoverable Read Error for a drive installed in a HP Modular Smart Array 20 Enclosure.
Component installer was enhanced to leave the component XML file (cpxxxxxx.xml) in a known location (%SystemDrive%CPQSYSTEM) so the HP Management and Version Control agents can retrieve information about the installed components on the server. Version:5.68.0.32 (9 Sep 2005) Resolved an issue where the cpqcisse driver does not work with external arrays. Updated Version Major Number for SmartStart 7.40. Version:5.66.0.32 (25 Apr 2005) Resolved the following:
- Issue wherein prior to hibernation, all the I/O was not completed and hence the controller cache was not flushed.
- Issue that can cause the Event Notification driver to crash when there are more than 7 disk drives on a SCSI Bus.
Version:5.64.0.32 (14 Feb 2005) Resolved a raidscan blue screen problem. Separated the cpqcissm.dll (DME) from the cpqcissm.sys driver package.
Updated the INF for 32 bit and 64 bit compatibility.
Increased the heartbeat timeout value during a firmware flash. Version:5.62.0.32 (18 Aug 2004) Updated controller lockup criteria to four minutes when flashing the controllers firmware. This is a driver workaround to accommodate the extended time required to update SA 6x firmware to revision 2.26. Version:5.60.0.32 (18 Jun 2004) Resolved the following:
- Bus reset issue
- Issue where events may be reported incorrectly when an external controller is removed and reinserted.
The driver now limits the number of commands sent to one for all logical Luns devices on the given external bus for Bus Resets.Driver now enables Pre-fetch for i386 based 6x controllers, thus improving performance. Firmware default is off. Added 4 point ID to txtsetup.oem for all SA5x and 6x. Version:5.49.2.32 (8 Mar 2004) Enabled Pre-fetch support to work in conjunction with HP ProLiant Smart Array 6x Controller Firmware version 1.92 or later for optimal performance. Version:5.48.0.32 (17 Dec 2003) Resolved the following:
- Spelling and grammatical errors in an event ids 24588, 24655, 24657, 24664.
- Issue with incomplete text displayed when event id 24606 is logged.
- Issue with a NTFS.sys E3 bug check that occurs when a drive fails in a RAID 0 raid set.
- Updated MapBuffers Parameter in the driver in order to prevent the system from using unecessary resources and additional memory.
Added the following:
- Documentation that lists the event log information posted by CPQCISSE.SYS.
- Support for the Smart Array 6404 Controller and Smart Array 6400 Controller.
- Added support for new location format:
Cabinet:Bay:Chassis:Slot
Version:5.46.2.32 (1 Jul 2003) Resolved the following:
- Events not being displayed correctly in DME.
- Updated naming convention for Array Configuration Utility(ACU).
- Removed references to Compaq within resource string files.
- Removed “Driver Posting Dialog Box”.
- Online flashing firmware issue with the SA641 and SA642 controller.
- Events reported on internal storage devices reported as external storage devices.
Modified the installer to disallow 32-bit drivers/applications from installing on 64-bit operating systems. Added support for the HP Smart Array 641/642/6402 controllers.Added support for Windows Server 2003. Updated INF to support DME on Windows Server 2003. Added Japanese translation.
Version:5.44.0.32 (11 Apr 2003) Resolved issue where in the IML event log, when a power failure was repaired, the failure was incremented instead of being updated to repaired.Resolved issue that was preventing Cpqcissm.dll from loading on Windows Server 2003. Added Japanese string support. Version:5.42.2.32 (12 Feb 2003) Updated the following:
- Resolved insertion string exceeding maximum length for logical drive change status event.
- Resolved issue with freeing all memory pools prior to unload for hot plug drive events.
- IMD and IML post some storage events inaccurately while other storage events do not get posted at all.
- Resolved issue where a tape drives Target ID increments by one and causes a unsafe removal message after every rescan of the device manager.
- Minimized the number of reads required to validate that the controller is alive and not locked up. This change should provide a a slight performance boost.
- Resolved an issue where filtered events where not being displayed under various multi language OS releases.
- Modified Redundancy page to not show disks that were on inactive nodes of a cluster.
Updated the following:
- Changed the max number of outstanding requests to 127 from 255.
- Changed the algorithm for checking the controller heartbeat to do less PCI configuration space reads. This may increase performance is some instances.
- Added support for Selective Storage Presentation.
- Added new Cache events for Internal Array Controllers.
- Added startup event and Cpqcisse.sys failed to start event.
- Added Snapshot events.
- Added new event codes for Physical Drive, Hardware Errors, Snapshot, and License keys
- Added new Cache events for Internal Array Controllers.
- Added property page for redundant controller paths.
Version:5.40.2.0 (D) (4 Dec 2002) Enhanced functionality. Version:5.40.2.0 (C) (15 Oct 2002) Updated for rebranding. Version:5.40.2.0 (B) (11 Jun 2002) Added support for Windows Server 2003. Version:5.40.2.0 (5 Jun 2002) Modified CPQCISSE to prevent logging all physical drive failure events to the IML as 'bay unknown'.Modified CPQCISSM.SYS to fix hibernation. Updated copyright information. Version:5.16.2.0 (B) (18 Jan 2002) Added text setup installation support for Microsoft Windows Server 2003. Version:5.16.2.0 (17 Jan 2002) Updated to prevent a potential system hang when waiting for Health Driver to load completely. Added support for:
- Smart Array 5312
- Clustering
Added new signatures for Cpqcissm and Cpqcisse. Version:5.12.88.0 (26 Sep 2001) Modified to enhance overall performance. Updated to correct potential problem when hot adding or removing drives. The event viewer may report the drives incorrectly. Version:5.10.84.0 (27 Jun 2001) Enhanced the installer to work with future deployment utilities. Version:5.8.76.0 (12 Apr 2001) Version:5.3.44.0 (11 Oct 2000) |
|